Revidyne Generator.lvlib:Revision Query.vi

Queries the current instrument firmware revision and instrument driver revision.

Refer to the Readme file for detailed driver information including modification history.


Connector Pane

Revidyne Generator.lvlib:Revision Query.vi


Front Panel

Revidyne Generator.lvlib:Revision Query.vi


Controls and Indicators

cvsrn

VISA resource name

A reference to the instrument in use. The reference to the resource name is created in the Initialize VI. Therefore, before calling this VI, you need to call the Initialize VI. To run this VI interactively, select the previously initialized resource name from the pull-down menu. To run this VI programmatically, wire the VISA resource name out terminal of the Initialize VI to subsequent VISA resource name input terminals. You chain instrument driver VIs together by wiring the VISA resource name out terminal to subsequent VISA resource name input terminals.

cerrcodeclst

error in (no error)

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

istr

Instrument Firmware Revision

Returns the instrument firmware revision numbers in the form of a string. This version and its capabilities are set by the instrument manufacturer.

istr

Instrument Driver Revision

Returns the instrument driver software revision in the form of a string.

ivsrn

VISA resource name out

A copy of the reference to the instrument in use. The reference to the resource name is created in the Initialize VI. Wire the VISA resource name out terminal of the Initialize VI to subsequent VISA resource name input terminals. You chain instrument driver VIs together by wiring the VISA resource name out terminal to subsequent VISA resource name input terminals.

ierrcodeclst

error out

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the error out control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

Revidyne Generator.lvlib:Revision Query.vi

Revidyne Generator.lvlib:Revision Query.vi

Revidyne Generator.lvlib:Revision Query.vi


List of SubVIs and Express VIs with Configuration Information

Revidyne Generator.lvlib:Error Query.vi

Revidyne Generator.lvlib:Error Query.vi

C:\workspace\Curriculum\Generator API\subVIs\Public\Utility\Error Query.vi


VI Revision History

"Revidyne Generator.lvlib:Revision Query.vi History"

Current Revision: 83


Position in Hierarchy

Revidyne Generator.lvlib:Revision Query.vi


Iconified Cluster Constants