Revidyne Generator.lvlib:Error Query.vi

Queries the instrument for any errors in the instrument's error queue. It will continue to read errors until all errors have been read from the instrument. Any errors will be returned in the error out control.

Note:

This VI is called automatically by most driver VIs so it is not usually necessary to call this in an application.


Connector Pane

Revidyne Generator.lvlib:Error Query.vi


Front Panel

Revidyne Generator.lvlib:Error Query.vi


Controls and Indicators

cvsrn

VISA resource name

A reference to the instrument in use. The reference to the resource name is created in the Initialize VI. Therefore, before calling this VI, you need to call the Initialize VI. To run this VI interactively, select the previously initialized resource name from the pull-down menu. To run this VI programmatically, wire the VISA resource name out terminal of the Initialize VI to subsequent VISA resource name input terminals. You chain instrument driver VIs together by wiring the VISA resource name out terminal to subsequent VISA resource name input terminals.

cerrcodeclst

error in (no error)

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ierrcodeclst

error out

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the error out control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ivsrn

VISA resource name out

A copy of the reference to the instrument in use. The reference to the resource name is created in the Initialize VI. Wire the VISA resource name out terminal of the Initialize VI to subsequent VISA resource name input terminals. You chain instrument driver VIs together by wiring the VISA resource name out terminal to subsequent VISA resource name input terminals.

istr

Error Message

Message returned by the instrument describing the instrument error(s).

i1di32

Error Code

The instrument-specific error code(s) returned by the instrument.


Block Diagram

Revidyne Generator.lvlib:Error Query.vi

Revidyne Generator.lvlib:Error Query.vi

Revidyne Generator.lvlib:Error Query.vi

Revidyne Generator.lvlib:Error Query.vi

Revidyne Generator.lvlib:Error Query.vi


List of SubVIs and Express VIs with Configuration Information

Error Cluster From Error Code.vi

Error Cluster From Error Code.vi

C:\Program Files\National Instruments\LabVIEW 2026\vi.lib\Utility\error.llb\Error Cluster From Error Code.vi


VI Revision History

"Revidyne Generator.lvlib:Error Query.vi History"

Current Revision: 100


Position in Hierarchy

Revidyne Generator.lvlib:Error Query.vi


Iconified Cluster Constants